—4— —5 — — 6 —
4. Hardware Installation Information
STEP 1: After removing the NPort 5200A series device server from the
box, connect the NPort 5200A series device server to a network. Use a
standard straight-through Ethernet cable to connect to a hub or switch.
When setting up or testing the NPort 5200A series device server, you
might find it convenient to connect directly to your computers Ethernet
port. In this case, use a cross-over Ethernet cable.
STEP 2: Connect the NPort 5200A series device server’s serial port to a
serial device.
STEP 3: Connect the power adaptor.
STEP 4: Placement options.
In addition to placing the NPort 5200A on a desktop or other horizontal
surface, you may also make use of the DIN-Rail or Wall Mount options,
as illustrated below.
5. Software Installation Information
To install NPort Administration Suite, insert the NPort Document &
Software CD into your computers CD-ROM drive. Once the NPort
Installation CD window opens, click on the Software folder, and then
follow the instructions on the screen.
To view detailed information about NPort Administration Suite, click
on the Documents folder, and then select NPort 5200A Series Users
Manualto open the pdf version of the users guide.
6. Pin Assignments
Ethernet Port Pinouts
Pin Number
Ethernet
1
Tx+
2
Tx-
3
Rx+
6
Rx-
NPort 5210A—DB9 male (RS-232) port pinouts
Pin Number
RS-232
1
DCD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
---
NPort 5230A—Terminal Block (RS-422/485) port pinouts
Pin
Number
RS-422/485
(4W)
RS-485
(2W)
1
TxD+(B)
---
2
TxD-(A)
---
3
RxD+(B)
Data+(B)
4
RxD-(A)
Data-(A)
5
GND
GND
NPort 5250A—DB9 male (RS-232/422/485) port pinouts
Pin
Number
RS-232 RS-422/
485 (4W)
RS-485
(2W)
1
DCD TxD-(A) ---
2
RxD TxD+(B) ---
3
TxD RxD+(B) Data+(B)
4
DTR RxD-(A) Data-(A)
5
GND GND GND
6
DSR --- ---
7
RTS --- ---
8
CTS --- ---
9
--- --- ---
7. Specifications
Power Requirements
Power Input
12 to 48 VDC
Power Consumption
119 mA@12V, 65 mA@24V
Operating Temperature
0 to 60°C (32 to 140°F), for standard models
-40 to 75°C (-40 to 167°F), for -T models
Operating Humidity
5 to 95% RH
Dimensions
100 x 111 x 26 mm
(3.94 x 4.37 x 1.02 in)
with ears
77 x 111 x 26 mm
(3.03 x 4.37 x 1.02 in)
without ears
Serial Line Protection
15 KV ESD for serial port
Level 1 Surge, EN61000-4-5
Magnetic Isolation
1.5 KV for Ethernet
Power Line Protection
Level 2 Burst (EFT), EN61000-4-4
Level 3 Surge, EN61000-4-5
Regulatory Approvals
FCC Class A, CE Class A, UL, LV D
Click here for online support:
www.moxa.com/support
The Americas:
+1-714-528-6777 (toll-free: 1-888-669-2872)
Europe:
+49-89-3 70 03 99-0
Asia-Pacific:
+886-2-8919-1230
China:
+86-21-5258-9955 (toll-free: 800-820-5036)
2010 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.