EasyManua.ls Logo

mr. steam MX5E - User Manual

Default Icon
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
mr
.
steam
®
Feel Good Inc.
®
____________________
IMPORTANT:
Leave this material with the homeowner.
____________________
Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential
Models: MX4E-6E

Other manuals for mr. steam MX5E

Questions and Answers

  • C
    Christine McintyreAug 16, 2025
    What to do if H20 water level is not satisfied within 5 minutes in Mr. Steam Bathroom Fixtures?
    • C
      Christopher RobertsonAug 16, 2025
      If the H20 water level isn't satisfied within 5 minutes in your Mr. Steam Bathroom Fixtures, here's what to check: 1. Ensure the water supply is turned on. 2. Inspect and replace the water solenoid valve if it's defective. 3. Examine and clean the water feed probe, and check its wiring. 4. Make sure the drain valve is closed. 5. Check and replace the AutoFlush if it's not functioning properly.
  • W
    williamswilliamAug 19, 2025
    Why does my Mr. Steam Bathroom Fixtures show Err1 Incorrect Field Supply Voltage?
    • R
      Randy ReyesAug 19, 2025
      If you're getting an Err1 error with your Mr. Steam Bathroom Fixtures due to incorrect field supply voltage, ensure the steam generator is supplied with the correct voltage as indicated on the data plate label.
  • R
    Rachel WrightAug 22, 2025
    What to do if Mr. Steam Bathroom Fixtures shows Err2 Button on control is pressed for more than 5 minutes?
    • M
      Mary BennettAug 22, 2025
      If your Mr. Steam Bathroom Fixtures shows Err2 because a button on the control is pressed for more than 5 minutes: * Remove and reinstall the control cover to address potential misalignment. * If there's debris behind the control cover, remove the cover and clean it, the control, and the keypad with a damp cloth.
  • P
    Patricia UnderwoodAug 25, 2025
    How to fix Prr1 Temperature Probe Error on Mr. Steam Bathroom Fixtures?
    • H
      Helen TorresAug 26, 2025
      If you encounter a Prr1 Temperature Probe Error with your Mr. Steam Bathroom Fixtures, the following steps can be taken: * Replace the control cable/MSTS if it is cut. * Replace the control/MSTS if there's an internal problem.
  • M
    Matthew DavisAug 28, 2025
    What to do if Mr. Steam Bathroom Fixtures shows Err7 Circuit Board malfunction?
    • J
      Jonathan ThomasAug 28, 2025
      If your Mr. Steam Bathroom Fixtures displays an Err7 Circuit Board malfunction due to a memory error, try pressing the ON/OFF button to clear it. If the code persists, replace the control.
  • T
    Tara SmithAug 31, 2025
    What to do if water level is not satisfied within 5 minutes in mr. steam MX5E?
    • A
      Andrew WhiteAug 31, 2025
      If the water level isn't satisfied within 5 minutes, here's what you can check: * First, ensure the water supply is turned on. * Next, inspect and if needed, replace the water feed solenoid. * Then, check and clean the water feed probe and its wiring. * Also verify that the drain valve is closed. * Finally, check or replace the AutoFlush if it's not functioning correctly.
  • S
    swilliamsSep 3, 2025
    Why is my mr. steam MX5E Portable Generator showing incorrect field supply voltage?
    • B
      Brenda JonesSep 3, 2025
      The steam generator might be showing an incorrect field supply voltage because the supplied voltage is not the voltage indicated on the data plate label. Make sure to supply the steam generator with the correct voltage.
  • W
    Wendy MooreSep 6, 2025
    What to do if there is memory error in Circuit Board of mr. steam Portable Generator?
    • K
      kdavisSep 6, 2025
      If you're seeing a memory error in the circuit board, try pressing the ON/OFF button to clear it. If the error code remains after doing so, the control might need to be replaced.
  • B
    billy68Sep 9, 2025
    What to do if there is debris behind control cover of mr. steam MX5E?
    • C
      crussellSep 9, 2025
      If there's debris behind the control cover, remove the control cover. Clean the cover, control, and keypad using a damp cloth.
  • M
    Meagan HaynesSep 12, 2025
    How to fix control cover misalignment in mr. steam MX5E?
    • A
      Alexander OrrSep 12, 2025
      To fix a control cover misalignment, remove the control cover and then reinstall it.

mr. steam MX5E Specifications

General IconGeneral
Brandmr. steam
ModelMX5E
CategoryPortable Generator
LanguageEnglish

Related product manuals