MicroTrap™ Operations Manual - Edition 4.4
26
Twist the shielding of the coax
and the PROBECABLE together.
Making sure that there is no
loose wires from the shielding
touching the center conductors,
continue to tape past the end.
Upon completion, the taped
connection should look as
shown above.
For strain relief, tie a loose knot down the cables from the
connection as shown above.
Twist the center
conductors together.
Pull the shielding wires back
along the cables and start taping
from the cable to the end.
Figure 2
MicroTrap
VOD/Data Recorder
MREL Product # 1-03-01
VOD PROBECABLE
MREL Product # 1-05-05
Rock Weight (See Figure 3)
RG-58 Coaxial
Cable 100 m (328 ft.)
MREL Product # 1-06-01
BNC Connector(Male)
Blasting Machine
Stemming
Bulk Explosive
Detonator & Booster
Blasthole
See Figure 2
Place the RG-58 Coaxial Cable
beside the leads from the
PROBECABLE.