Do you have a question about the MSA FSR W65 and is the answer not in the manual?
Brand | MSA |
---|---|
Model | FSR W65 |
Category | Respiratory Product |
Language | English |
Provides technical specifications and standards for different FSR models.
Details the meaning of standards and classifications for FSR models.
Push sealed opening lever upwards to break seal and pull off locking assembly.
Lift off case cover and discard.
Grasp filtering device by head strap and pull out of case.
Bend up nose clip and insert mouthpiece between lips and teeth.
Fit nose clip tightly.
Position head strap and shorten if necessary.
Put on helmet.
If case is dented, FSR can be used with bottom, but with increased inhalation resistance.
Inspect FSR for intactness before each shift and clean if necessary. Remove damaged devices.
Check FSR weight for moisture uptake; remove from service if weight increase exceeds limits.
FSR is designed for one-time use and is not reconditioned.
FSR life expectancy is based on random sample tests and serviceability of the lot.
Dispose of filter self-rescuer according to applicable National regulations.