EasyManua.ls Logo

MSA Luminator Cap Lamp - 8 Approvals; Marking, Certificates and Approvals According to the Directive 94;9;EC (ATEX)

MSA Luminator Cap Lamp
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Luminator Cap Lamp
15
Approvals
GB
8Approvals
8.1 Marking, Certificates and Approvals according to
the Directive 94/9/EC (ATEX)
Special conditions for safe use:
In hazardous locations the Multifunctional LED-Lamp type LUMINATOR has to
be used according to the following regulations:
- The device has to be carried at the body. Don't put the device away out of
your supervision. This is to prevent the device from electrostatic charge.
- The charging of the LUMINATOR is only allowed outside of the hazardous
area.
- For charging follow the manual instructions (5 V/1 A, U
m
= 7 V).
Special conditions for safe use:
The antenna used for the activation of the transponders in an hazardous area
must only be with the RF radiation power not exceeded 6 W for Group I and 2 W
for Group IIC.
Manufacturer: MSA AUER GmbH
Thiemannstraße 1
D-12059 Berlin
Product: LUMINATOR
EC-Type Examination Certificate: BVS 13 ATEX E 076
Type of protection: EN 60079-0:2012, EN 60079-11:2012
Marking:
I M1 Ex ia I Ma
II 1G Ex ia IIC T4 Ga
-20°C Ta +60°C
Battery: LiFePO4 3,6 V / 9000 mAh
U
m
: 7 V
Quality Assurance Notification: 0158
Year of Manufacture: see Label
Serial Nr.: see Label
RFID TAG: The instrument is installed with an pas-
sive RFID-TAG: FTZU 11 ATEX 0177 X.