TAL 0110 (L) Rev. 8 - 10020949
CHARGING THE BATTERY PACK
2. Push the plug into the female con-
nector and turn the ring _ turn to
secure it.
3. Plug the charger into a 115-120 V,
50, 60 Hz (standard AC) outlet. The
charger can be used internationally
with the appropriate adapter.
Voltages lower than 115V are not rec-
ommended. Voltages greater than
120V will damage the battery charger
and battery pack.
4. Charge the battery pack until a full
charge is indicated.
The charger uses one LED. When the
battery is charging, the LED will be
Red. When the LED is Green the bat-
tery is fully charged. The battery can
stay connected to the charger until it is
needed. If the LED is Amber, the bat-
tery is not at the proper temperature.
The charging will start when the battery
pack reaches the optimum charging
temperature of 35°F to 100°F. If the
LED is flashing Red, there is a failure.
Disconnect battery pack, and unplug
charger. Plug charger back into outlet
and reconnect battery pack to reset
charger. If LED flashes Red during any
part of the charge, after it has been
reset, remove the battery from service.
10
LED Signaling
Condition LED Indication
Rapid Charge Red
Charge Complete Green
Charge Pending Amber
Charge Failure Red Flash
No AC or No Battery OFF