EasyManua.ls Logo

MSA V Series - Periodic examination; Function test SRL Mode and cable examination

MSA V Series
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
72 73
Periodic examination
Function test SRL Mode and cable examination
9
Issue identied
Proceed to examination 10
x3
Ensure gloves, safety shoes and safety glasses are
worn.
Set up the Tripod (max height), attach the Pulley and
Rescuer as for use.
Ensure selector switch is in SRL mode.
• Fully extract entire length of cable at the same time
examining cable (specic to model).
• In a controlled manner allow the cable to retract.
• Perform 3 x lock on test at the end middle and
beginning of cable length during retraction.
To perform a lock on test. Grasp the cable tightly with
a gloved hand. Pull down sharply, the SRL should
lock, stopping any further extraction of the cable.
Release the tension on the cable to return to normal
operation.

Related product manuals