Degraded RAID Array
A RAID 1, RAID 5 or RAID 10 volume s reported as degraded when one of ts hard drve 
members fals or s temporarly dsconnected, and data mrrorng s lost. As a result, the 
system can only  utlze the remanng  functonal hard drve  member. To re-establsh 
data mrrorng and restore data redundancy, refer to the procedure below that corre-
sponds to the current stuaton.
Mssng Hard Drve Member
Make sure the system s powered o. 
Reconnect the hard drve. 
Reboot the system to Wndows; the rebuld wll occur automatcally.
Faled Hard Drve Member 
Make sure the system s powered o. 
Replace the faled hard drve wth a new one that s of equal or greater capacty. 
Reboot the system to Intel RAID Opton ROM by press <Ctrl> and <I> keys smul
-
taneously durng the Power-On Self Test (POST).
1.
2.
3.
1.
2.
3.
Select the port of the destnaton dsk for rebuldng, and then press ENTER.
4.
RAID Volumes
ID      Name                Level                     Strp     Sze                Status            Bootable
0        Volume0           RAID 1(Mrror)       N/A      XXX.XGB       
Degraded        Yes
Physcal Dsks:
Port   Devce Model     Seral #    Sze  Type/Status(Vol ID)
1        XXXXXXXXXXXXX     XXXXXXXXXXXXX  XXX.XGB  Member  Dsk (0)
2        XXXXXXXXXXXXX     XXXXXXXXXXXXX  XXX.XGB  Member  Dsk (0)
Press  <CTRL-I>  to enter Conguraton Utlty..  
DISK / VOLUME INFORMATION
[                                                ]
4.       Recovery Volume  Optons
4.       Recovery Volume  Optons
5.       Ext
RAID  Volumes :
None  dened.
Physcal  Devces :
Port  Devce  Model                 Seral  #                                                  Sze    Type/Status (Vol  ID)
1       XXXX-XXXXXXXX          XXXXXXXXXXXXXX                    XXX.XGB    Non-RAID  Dsk
2       XXXX-XXXXXXXX          XXXXXXXXXXXXXX                    XXX.XGB Non-RAID  Dsk
[ ↑↓] - Select                          [ESC] - Ext                        [ENTER] - Select Menu
1.       Create  RAID  Volume
2.       Delete  RAID  Volume
“Degraded” volume and dsk avalable for rebuldng detected. Selectng
a dsk ntates a rebuld. Rebuld completes n the  operatng system.
[                                                             ]
DEGRADED VOLUME DETECTED
Select the port of the destnaton dsk for rebuldng (ESC to ext): 
[ ↑↓] - Prevous/ Next      [ENTER] - Select      [ESC] - Ext
Port   Drve   Model  Seral  #    Sze   
1        XXXX-XXXXXXXX   XXXXXXXXXXXXXX            XXX.XGB  
[                        ]
MAIN  MENU