Reliably Serving a Thirsty World
®
1770 Brackett St., La Verne CA 91750 USA
•
T:
909-629-7301
•
F:
909-629-7380
•
www.mtnproducts.com
•
sales@mtnproducts.com
POU Install
•
X ranges from 0 to 24. 0 means turn off SIP
® mode. Example: If initial POU
installation was completed at 12 noon, entering setup mode and pushing auto
clean button 12 times (1 push of the button equals 1 hour) and then pressing
the “Water” dispense button to lock in setting, the cooler will start Auto SIP
mode at midnight.
•
The system automatically exits setup mode if the water dispense button is not
pressed within 15 seconds of pressing auto clean button. Pressing any other
buttons other than SIP auto clean or water dispense will exit set up mode.