Temposonics
®
R-Series V PROFINET IO RT & IRT
Operation Manual
I 29 I
,QGH[ Sind
in arra
a t tp ttrit ata tp sription

Snsor stats
0 Number of entries Variable ro Integer32
1 Time since last update Variable ro Integer32 Age of the status data in ms
2 Status data version Variable ro Integer32 Version number
3 Operational time Variable ro Integer32 Total operational time of the sensor
4 Odometer Variable ro Integer32 Total distance travelled by the position magnet in cm
5 Magnet cycles Variable ro Integer32 Total number of directional changes of the magnet
6 Minimum input voltage Variable ro Integer32 Minimum input voltage so far in mV
7 Maximum input voltage Variable ro Integer32 Maximum input voltage so far in mV
8 Current input voltage Variable ro Integer32 Current input voltage
9 Minimum temperature Variable ro Integer32 Minimum temperature inside the sensor electronics housing so far in °C
10 Maximum temperature Variable ro Integer32 Maximum temperature inside the sensor electronics housing so far in °C
11 Current temperature Variable ro Integer32 Current temperature inside the sensor electronics housing in °C
12 Input voltage out of range Variable ro Integer32 Duration of exceeding or falling below the permissible power supply
range in ms
13 Temperature out of range Variable ro Integer32 Duration of exceeding or falling below the permissible operating
temperature range in ms
14 Reserved for future use Variable ro Integer32 Reserved for future use
15 Reserved for future use Variable ro Integer32 Reserved for future use
16 Reserved for future use Variable ro Integer32 Reserved for future use
17 Reserved for future use Variable ro Integer32 Reserved for future use
18 Reserved for future use Variable ro Integer32 Reserved for future use
Reading additional information regarding the sensor status: In parallel to the position values and the velocity values, the sensor can output
further information on the sensor status via the PROFINET protocol. This information is stored in an array with 19 Integer32 values, which you
call via the address API 0 Slot 0 Subslot 1 Index 2000.
Fig. 48: Array with additional information regarding the sensor status

Other manuals for MTS Sensors Temposonics R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Sensors Temposonics R Series and is the answer not in the manual?

MTS Sensors Temposonics R Series Specifications

General IconGeneral
BrandMTS Sensors
ModelTemposonics R Series
CategoryAccessories
LanguageEnglish

Related product manuals