Communications
COM setting Set up the COM port inside the PC according to the following list.
• Baud rate: 9600/19200/38400/57600/115200 (the factory baud rate of the power supply: 115200)
• Parity bit: None
• Data bit: 8
• Stop bit: 1
• Data ow control: None
RS485 communication commands add the address after the command letters. Taking ID equalling 5 for example:
ISET05:10.5
Set the current to 10.5A
ISET05?
Query the current setting value of the current
VSETO5:12.5
Set the voltage to 12.5V
VSET05?
Query the current setting value of the voltage
IOUT05?
Query the current output value of the current
VOUT05?
Query the current output value of the voltage
BEEP05:
BEEP:l turn on the buzzer,BEEP: 0 turn o the buzzer
OUT05:
OUT: 1 turn on the output,OUT: 0 turn o the output
OUT05?
Returning the output status of the machine, 0 is output OFF while 1 is output ON.
STATUS05?
Query the device status BIT0:CC/CV, BIT1:output, BIT2:V/C priority, BIT4:the buzzer, BITS: LOCK, BIT6:0VP status,
BIT7:0CP status.
*IDN05?
Query the serial No. of the device
RCL05:5
Recall M5 as the current value (the value is 1- 5)
RCL05:6
Recall LIST dynamic value
SAV05:5
The current value is stored in MS (the value is 1- 5)
OCP05:12.5
Set the OCP current value to be 12.5A
OCP05: ON/OFF
open/close OCP
OCP05?
Query the OCP current value
OVP05:15.5
Set the OVP voltage value to be 12.5A