Continued from previous page.
4
Press the
2
key to select PRODUCT SENSOR.
5 Sensor drive #3 should ideally be between 90-110.
6 If the labeler has not been feeding correctly and sensor drive #3 is not between these values you
should loosen the top half of the product sensor and move it until the values fall between 90-110.
When the numbers are in range tighten the top half of the sensor drive to lock it in place.
7
Press the
CLEAR
CANCEL
key until you return to the READY screen.
8
Press the
SET PROD
.
THICKNESS
key. The labeler product sensor is now ready. It is recommended that you save
your settings.
Note - For alternate or non-standard sensor setup go to page 50.