CAUTION
Using too much force while pulling down on
the plastic mounting plate could cause damage
to the plate.
Pull gently down on the mounting plate until
the product tubing can be accessed. With the
tubing now accessible pull down on the tubing
lowering the dispense manifold as far down as
possible. Now locate the tubing inside of the
refrigerated cabinet.
The tubing is towards the upper right rear inside
of the cabinet and is separated by the chase
that runs upwards towards the dispensing area.
Push the tubing upwards as far as possible.
Return to the dispense area and pull the tubing
downwards as far as possible. Return to the
inside of the cabinet and push the tubing
upwards as far as possible. Repeat the pulling
of the tubing downwards in the dispense area
and the pushing up of the tubing inside of the
cabinet until the top of the dispensing plate is
easily accessible.
Doing so makes the replacing of the LMS Valves
much easier.
6. Using a Phillips head screw driver remove the
two (2) screws from the metal mounting plate
that secures a block of three (3) LMS valves to
the dispensing valve mounting plate.
NOTE: The tubing is numbered and will need to be
returned to the same position within the dispensing
mounting plate following the replacement of the
LMS valves. Tubing is positioned 1-8 in a counter
clockwise manner with Water being the 9
th
tube.
Remove the remaining two (2) blocks of three (3)
valves from the dispensing mounting plate.
Wash, rinse, and sanitize the dispensing mounting plate.
Multiplex
2100 Future Drive
Sellersburg, IN 47172
Phone: 844-724-2273
Fax: 920-683-7592
Page 4 of 13
2020 Tune Up, continued