Why does the compressor run for long periods in my Multiplex Blend-In-Cup MA-8-2 Beverage Dispenser?
- UurothAug 7, 2025
If the compressor in your Multiplex Beverage Dispenser runs for extended periods, several factors could be the cause. First, too much warm product may have been placed in the cabinet; allow sufficient time for cooling. Second, check for prolonged door openings or doors left ajar; ensure doors are closed when not in use and avoid keeping them open for too long. Third, inspect the door gaskets for proper sealing; adjust the door or replace the gasket if needed. Fourth, a dirty condenser coil can cause this issue, so clean the coil. Finally, the evaporator coil might be iced over; turn off the unit to defrost it, ensure the thermostat isn't set too low, and check the gasket condition.