UTC-4201A
OUTPUT SPECIFICATION
AUXILIARY SUPPLY:
TEMPERATURE CONTROLLER
Relay
Supply voltage
Relay Type
Power consumption
(VA RATING)
Rating
1 nos.
1 C/O (NO-C-NC)
Approx 4 VA @ 230V AC MAX
5A, 230V AC/30 V DC
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
Operating Temp.
0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
100 to 270V AC, 50-60Hz
Input Types
Resolution
Indication
Accuracy
Input Range
0 to 600°C,
0 to 1200°C,
-99 to 400°C,
-99.9 to 400.0°C,
J
K
PT-100
PT.1
J,K,PT-100 = 1°C
±1% of FSD ± 1°C
PT.1 = 0.1°C
Display
Heating
Size
Keys
Cooling
Panel Cutout
Upper: 4 digit, 7 segment, 0.56” Red
1) PID control with Auto-Tuning
1) BL.TP (Blower Time Proportion)
Lower: 4 digit, 7 segment, 0.33” Green
2) ON-OFF control
2) ON-OFF control
48 (H) x 48 (W) x 95 (D) mm
SET, INC, DEC, ENT
45 (H) x 45 (W) mm
TECHNICAL SPECIFICATION
(FSD:- full scale deflection)
CONTROL METHOD:
INPUT SPECIFICATION:
DISPLAY AND KEYS:
DIMENSION:
CONTROL METHOD:
Relay Output
48
95
45
45
3
MECHANICAL INSTALLATION
TERMINAL CONNECTION
48
Outline Dimension (mm)
Panel Cutout
Dimension (mm)
PV = Process value
SV = Set Value
Alarm
Inband, Absolute Outband, High,
Absolute Low
Analog Output
0 TO 10V DC
T/C
+
+
RTD
-
-
NC
C
R1
NO
O/P
0TO10V
DC
!
100
270VAC

1
2
3
4
5
L
N
6
7
8
9
10
~
50/60HZ
4VA
Made in India
www.multispanindia.com
O/P
R
TUNE
SET
ENT
UTC 4201A
SV
PV

Other manuals for MULTISPAN UTC-4201A

Question and Answer IconNeed help?

Do you have a question about the MULTISPAN UTC-4201A and is the answer not in the manual?

MULTISPAN UTC-4201A Specifications

General IconGeneral
TypeDigital
MountingWall Mount
Stages1
Accuracy±1°C
OutputRelay

Summary

Controller Specifications and Features

Input and Control Capabilities

Describes input types, ranges, resolution, accuracy, and control methods for heating, cooling, and alarm.

Installation, Maintenance, and Safety

Safety Precautions and Warnings

Covers essential safety rules, electrical shock warnings, and best practices for safe operation.

Control Logic Configuration

Control Parameter Setting

Details setting control parameters for PID, ON-OFF, and BL.TP modes.

Case-Specific Control Settings

Outlines parameter settings for Heat, Cool, and Alarm control cases.

Control Functions and Auto-Tuning

Auto-Tuning Functionality

Explains the auto-tuning process for PID parameters and its behavior.