EasyManua.ls Logo

Multitech MTC-MAT1-B01 - Configuring Device as UDP Client to Connect to UDP Server

Multitech MTC-MAT1-B01
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONFIGURING AND COMMUNICATING WITH YOUR DEVICE
30 MultiConnect
®
Cell MTC Cat M1 User Guide
Enter:
Should return:
AT+CEREG? 0,1
OK
3. Configure socket parameters
Enter:
AT#SCFG=1,3,300,240,600,50
4. Activate context one
Enter:
AT#SGACT=1,1
5. Set firewall rule to accept connections:
AT#FRWL=1,"###.##.###.#","###.##.###.#"
where ###.##.###.# represents the IP range. For example:
AT#FRWL=1,"204.26.122.1","204.26.122.255"
6. Set connection ID 1 for UDP listening mode on port 7000.
Enter:
AT#SLUDP=1,1,7000
The device responds with and unsolicited indication that a host is trying to connect to connection ID 1 on
port 7000.
SRING: 1
7. Accept incoming connection ID 1
Enter:
AT#SA=1
The device indicates a client successfully established a listener connection.
CONNECT
The device can send and receive data now.
Exit Data Mode and Close Connection
To exit data mode and close the socket:
1. Enter the escape sequence:
+++
2. To close Socket 1, enter:
AT#SH=1
3. To close the data connection, enter:
AT#SGACT=1,1
The device responds with OK.
Configuring Device as UDP Client to Connect to UDP Server
Configure and Connect the Device
To configure the device as a UDP client:
1. Check signal strength.
Enter:

Table of Contents