© Munters AB, 2015 80
The following is a typical scenario:
A loading truck will come to fill the bin or silo. Define the Filling Detection Weight to stop the augers
from operating during a loading event (Default: 300 Kg). Next, a Minimum Filling Weight needs to be
defined in order to have the filling event recorded in the Feed Inventory (Default: 2000 Kg). Once the
loading of the feed is finished, the timer begins to count down for the augers to resume normal operation
(Resume Time, Default: 5 minutes) and for the filling event to be recorded as completed.
6.5 Bird Curve
This screen displays data according to growth day for broilers, turkeys, or breeders, previously set in
General Settings.
NOTE: Only Broilers/ Layers Mode support this function.
Edit the growth days and weights for the bird curves to fit individual preference.
6.5.1 B
IRD
C
URVE
H
ELP
|
S
ET
D
EFINITIONS
While viewing the
Bird Curve
menu: Press
HELP
, select
SET
and press
ENTER.
• Bird Curve Offset: Enter the factor used to adjust the weight curve. This amount is added to the
“Now” field. Range: 0.0 – 10.0 Kg/Lb.
6.6 History
The scale history shows bird weight statistics. You can review daily data for each scale, or separately. The
unit records up to two-bird scale data; if you have more than one scale-1 or one scale-2, their data is
combined.
NOTE: Only Broiler/Layers Mode supports this function
7
14
21
28
35
42
0.31
0.66
1.26
2.07
3.15
4.45
0.35
0.70
1.54
2.73
4.27
6.15