EasyManua.ls Logo

Murdock A171.8 Series - User Manual

Default Icon
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS
7020-904-001
A171.8 Series
Barrier Free, Wall Mounted Water Cooler
A171108F / A171408F / A171108S / A171408S
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
Date: 09/07/18
COMPLIES WITH
Test rating conditions are
compliant with ARI 1010.
Federal
Public Law
111-380
(No Lead)
Member of
MURDOCK
15125 Proctor Ave.
City of Industry, CA
91746 U.S.A.
Phone 800-591-9360
626-336-4561
Fax 626-855-4894
www.murdockmfg.com
LIMITED WARRANTY - UNITED STATES & CANADA
LIMITED EXPORT WARRANTY - One year on parts only.
Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18)
months after the date of shipment from the factory, whichever comes first.
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship
under normal use for an additional four (4) years from the end of the one (1) year period described above.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty.
Stainless steel must be protected on job site during construction and must be properly maintained after the water
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.
Murdock assumes no responsibility for use of void or
suspended data. © Copyright Murdock, City of
Industry, CA Member of Morris Group International.
Please visit www.murdockmfg.com for most
current specifications.

Other manuals for Murdock A171.8 Series

Questions and Answers

  • K
    Karen ParksAug 10, 2025
    Why is the compressor cycling on overload protector in my Murdock A171.8?
    • J
      Joshua HoganAug 10, 2025
      If your Murdock Water Dispenser's compressor is cycling on the overload protector, this could be due to a dirty condenser or a blocked fan, which causes high head pressure and frequent cycling of the overload protector. Also, ensure the incoming voltage is within 10% of the Serial Nameplate rating. If these steps don't resolve the issue, the overload or relay might be defective and need to be changed. For restrictions or moisture in the system, contact a certified refrigeration mechanic.
  • M
    Melinda NelsonAug 15, 2025
    What to do if my Murdock A171.8 has restricted or no water flow?
    • D
      Danny JohnsonAug 15, 2025
      If your Murdock Water Dispenser is experiencing restricted or no water flow, start by ensuring the Water Supply Service Stop Valve is fully open and that there is a minimum 20 PSIG (168 kPa) supply line flow pressure. Check for any twists or kinks in the Bubbler Tubing. Also, the Water Inlet Strainer may be blocked with sediment, so clean the screen, and replace it if needed. The Cartridge Valve located in the Water Control assembly or Bubbler can also become clogged with foreign material, and it can only be replaced. Finally, check the flow adjustment. If the issue is related to refrigeration or thermostat failure, a qualified technician should check the water cooler.
  • C
    clinekristinAug 20, 2025
    Why is the water warm when the compressor runs on my Murdock A171.8 Water Dispenser?
    • L
      Lindsey LongAug 20, 2025
      If your Murdock Water Dispenser's compressor is running but the water is warm, it could be due to a loss of refrigerant, which requires a certified refrigerant technician for repairs. Ensure the Condenser Fan Motor is working, and the Fan Blade turns freely to remove heat. An incorrect refrigerant charge, restriction, or defective compressor also indicate a problem within the refrigeration system, requiring inspection by an authorized service company.
  • S
    spaulAug 25, 2025
    How to fix water dripping or not shutting off in my Murdock A171.8 Water Dispenser?
    • K
      Kevin HolderAug 26, 2025
      If your Murdock Water Dispenser is dripping water or won't shut off, remove the Pushbutton. Adjust the Flow Regulator to the highest setting using a flat head Screwdriver and turning clockwise. If the water no longer drips, turn the Screwdriver counter-clockwise until you have the desired flow rate, and ensure the Retaining Nut is tightened to the Valve assembly to 25 in-lb torque. If the issue continues, the Flow Regulator Cartridge may need replacement.
  • J
    Jennifer PetersonAug 30, 2025
    Why is my Murdock A171.8 Water Dispenser making so much noise?
    • A
      Anthony KennedyAug 30, 2025
      If your Murdock Water Dispenser is operating noisily, first check that the Fan Blade is rotating freely. Ensure the Water Cooler is correctly mounted to the wall, as the absence of the two lower mounting bolts may cause excess noise and vibration. Check the Compressor mounting to ensure the Pins and Clips are not rattling. If the Compressor appears noisy internally, it must be replaced.
  • J
    Joshua CopelandSep 4, 2025
    How to troubleshoot a Murdock A171.8 Water Dispenser when the compressor does not run?
    • J
      Jonathan JonesSep 4, 2025
      If the compressor on your Murdock Water Dispenser does not run, check the Power Supply Cord and the electrical Receptacle for power and correct voltage (within 10% of the rated voltage on the Serial Nameplate). Check for loose wires within the Compressor Box, ensuring the incoming power Leads are connected to the Overload and Relay. If all components check positive for continuity, test the Wiring Harness Plug for continuity to see if there is a broken Wire within the Wiring Harness insulation. If the Capillary Bulb loses its charge or becomes kinked, unplug the Water Cooler and check for continuity across the two electrical Terminals on the Thermostat using an ohm Meter; install a new Thermostat if there is no continuity.