EasyManuals Logo

Murphy LM500 Assembly Instruction

Murphy LM500
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
00020785
11022011
Section15
1
Bubble Lens Assembly Instruction (LM500/LM500-TF)
WARNING:Performallins t alla tionswiththepow ersour ceOFF.Be sureenginehas
cooledandpr e ssur e hasbeenr eliev e d.Followallsafetypr acti ce stopr ev en tSEVERE
BURNS.
1
RemoveLensfrompackingmaterial.
Inspectforcosmeticflaws,scratches,orfingerprintsonthebubblelens.
Cleanasnecessaryusingasoftclothwithverymilddetergent&water,orisopropylalcohol.
2
Insertlargecutoutofdialintothelenssidewithlargernotchatan
angleasshown.
3
Pressthesmallendofthedialcutoutinwithboththumbsuntil
fullyseated.
4
Carefullyplaceoringaroundthelens.

Other manuals for Murphy LM500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Murphy LM500 and is the answer not in the manual?

Murphy LM500 Specifications

Connections IconConnections
Crankcase balance vent connection1/2 NPTF (top)
Inlet connection2 x 3/4 NPTF (side)
Conduit connection1/2 inch conduit (female, top)
Switch Specifications IconSwitch Specifications
Snap-switch SPDT rating (AC)10 A, 125 VAC
Snap-switch SPDT rating (DC)0.5 A, 125 VDC, 10 A, 30 VDC
Pressure and Temperature IconPressure and Temperature
Maximum inlet pressure9.50 psi/25 ft. oil (head pressure)
Maximum differential pressure2 in (51mm) between running and stopped
Maximum ambient temperature250°F (121°C)
Physical Characteristics IconPhysical Characteristics
Wire leads length14 in +/- 2 in (355 mm)
Case materialDie cast aluminum
Lens materialClear “Frog Eye” non-staining, high impact, high temperature nylon

Related product manuals