10
2E – MAINTENANCE
1- Descale the boiler, the internal surface of
the tank and the appliance water piping
once or twice a year.
2- Descale the rinse and wash jets every
month using vinegar or a descaling agent.
3- The internal hose of the rinse aid and
detergent peristaltic dispenser should
undergo periodic maintenance (once or
twice a year).
4- Clean solenoid valve filter by removing it
from the inside of the valve and
unplugging the water inlet tube.
2F – UNINSTALL (Long period of
inactivity)
Machine can only be taken out of
operation by trained technicians
authorized for the purpose, who will
perform the following:
1- Shut off water line (water valve) and
electric supply (main breaker).
2- Completely drain the tank.
3- Remove and carefully clean the filters.
4- Completely drain the dispenser hoses,
removing them from the containers.
5- Drain the detergent and rinse aid nozzles
with fresh water first and then with water
and glycerin (50% - 50%) taking care that
nozzles remain clean and lubricated inside.
6- Drain the booster completely by removing
the screw located under the machine.
7- Spread a thin film of vaseline oil over all
the stainless steel surfaces.
INSTALLER REMARKS
INSTALLATION DATE:__________________________
INSTALLATION PLACE:_________________________
INSTALLER NAME:__________________________
MACHINE SERIAL NUMBER:___________________
SIGNATURE:____________________________________