EasyManua.ls Logo

MWM Acteon 412TCE - Relação de Falhas Listado de Fallas Failures List

MWM Acteon 412TCE
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54 9.612.0.006.7162
RELAÇÃO DE FALHAS
LISTADO DE FALLAS
FAILURES LIST
SINTOMA
SINTOMA
SYMPTOM
CAUSAS PROVÁVEIS
CAUSAS PROBABLES
POSSIBLE CAUSES
Baixa rotação de partida
Baja rotación al arranque
Low starting speed
01-02-03
Motor não pega
El motor no arranca
Engine does not start
05-06-07-08-09-10-14-15-16-17-22-23-25-26-27-
29-40-53-67
Partida difícil - (Motor demora a pegar)
Arranque difícil - (Motor arranca con dificultad)
Difficult start - (engine does not starts quickly)
01-02-03-05-07-08-09-10-14-15-16-17-18-22-25-26-
27-29-40-53-67
Falta de potência / Desempenho
No hay potencia / Desempeño
Lack of power / Performance
07-08-09-10-14-15-16-17-18-19-20-21-
22-23-25-26-27-29-32-44-53-54-56-57-67
Motor falhando
Motor falla
Engine misfiring
07-08-09-10-14-15-16-17-19-20-21-22-
23-24-26-29-32-44-53-67
Consumo excessivo de combustível
Consumo excesivo de combustible
Excessive fuel consumption
09-14-15-17-18-21-22-23-25-26-27-
29-32-57-60-67

Table of Contents