Installation Videos:
MY
FireplaceBlower
MyFireplaceBlower.com:
Installation Instructions:
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2014
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
Drywall dust or other fragments may be present in your replace’s vent space, clean this area before you install the
blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
Instructions for Design Version - GFK-160A Blower Kit with Cord Set
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number
for Supplemental Information before starting installation. Blower operates on 120V/60Hz power.
CLICK
High Quality Aftermarket Fireplace Blowers & Fans
1-800-466-4045
Check the contents of the carton.
Make sure nothing was damaged in shipment.
Do NOT install a damaged blower kit!
Blower Kit Parts
Step 1: Turn Off Fireplace and allow it to
cool down. Disconnect from 120V Power. Shut
off the Gas supply. Remove the louver which
covers the lower vent space below the rebox.
Lay cord set out in a straight line, with the
3-Prong Power Plug furthest away from the
replace.
Figure: 1
Step 2: Connect black and white wires of power cord
to either metal spade attached to motor; push discon-
nects onto the metal tabs. Use small screw to ground
ring terminal to small hole on end of fan. (Figure: 1)
CLICK
CLICK
NOTE: Diagrams and Illustrations NOT to Scale
Page 1 of 5
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK!
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set;
Preventing it from making contact with moving or hot objects.
Description
Qty.
Blower - Magnetic Mount
Thermodisc / Heat Sensor
Variable Speed Control
Power Cord
3-Prong to 2-Prong Adapter
Installation Instructions
(Downloadable)
1
1
1
1
1
1
1
Jumper Wire (Black)
Small Ground Screw
1
Position blower with rectangle air exit ports facing up
and motor facing left. Slide blower into lower vent
space centered against the rear wall.(Figures: 1,3&16)
For “SL” Series, see (Figures: 5&14); a removable
cross-member bar may be present.
•Does not matter which metal tab you
connect the black and white wires to.