EasyManua.ls Logo

My Fireplace Blower AUB User Manual

Default Icon
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Exhaust Air
to
Outside
BLOWER
Room Air
in Bottom
Heated Air
Out Top
Diagram Not to Scale
Installation Videos:
MY
FireplaceBlower
MyFireplaceBlower.com:
Installation Instructions:
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2017
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
Drywall dust or other fragments may be present in your replace’s vent space, clean this area before you install the
blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
Instructions for AUB Blower Kit with Cord Set
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number
for Supplemental Information before starting installation. Blower operates on 120V/60Hz power.
CLICK
High Quality Aftermarket Fireplace Blowers & Fans
1-800-466-4045
Check the contents of the carton.
Make sure nothing was damaged in shipment.
Do NOT install a damaged blower kit!
Blower Kit Parts
Step 1: Turn O Fireplace and allow it to cool
down. Disconnect from 120V Power. Shut o
the Gas supply.
Lay cord set out in a straight line, with the
3-Prong Power Plug furthest away from the
replace.
Step 2: Push the green wire disconnect onto the gold
ground tab on the end of fan.
Connect white and black wires of the cord set to either
of the wires coming from the motor. Push disconnects
together. (Figure: 1)
CLICK
CLICK
NOTE: Diagrams and Illustrations NOT to Scale
Page 1 of 3
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK!
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set;
Preventing it from making contact with moving or hot objects.
Description
Qty.
Fan
Thermodisc / Heat Sensor
Variable Speed Control
Cord Set & 3-Prong Adapter
Velcro Strip
Foam Dampening Pad
Installation Instructions
(Downloadable)
1
1
1
1
1
1
2
Cable Quick Connect Ties
2
Step 3: Remove the screen by lifting it up and away
from the replace. Remove the door by releasing the
four latches.
Question and Answer IconNeed help?

Do you have a question about the My Fireplace Blower AUB and is the answer not in the manual?

My Fireplace Blower AUB Specifications

General IconGeneral
BrandMy Fireplace Blower
ModelAUB
CategoryBlower
LanguageEnglish

Summary

Blower Kit Parts

Step 1: Turn Off Fireplace

Turn off fireplace and disconnect from 120V power. Shut off gas supply.

Step 2: Connect Wires

Connect the green wire to the ground tab, then connect white and black wires to the motor.

Step 3: Remove Fireplace Screen and Door

Remove the fireplace screen and door by releasing the latches.

Blower Installation Steps

Step 4: Mount Blower Assembly

Wipe mounting area, visualize pathway, attach blower to side wall with velcro.

Step 4: Place Magnetic Thermodisc

Place thermodisc 2 inches left of ignitor, 3 inches back, ensuring metal contact.

Step 5: Connect Variable Speed Control

Mount speed control, turn dial to reduce speed, channel wires, plug in transformer and blower.

Finishing Steps

Restore Gas and Power

Turn the gas supply back on if applicable. Reconnect 120 Volt power.

Wiring Connections Overview

Overview of wiring connections including receptacle, junction box, and blower components.