EasyManua.ls Logo

My Fireplace Blower FBK-250 - User Manual

Default Icon
5 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation Videos:
MY
FireplaceBlower
MyFireplaceBlower.com:
Installation Instructions:
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2015
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
Drywall dust or other fragments may be present in your replace’s vent space, clean this area before you install the
blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
Instructions for FBK-250 Blower Kit with Cord Set
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number
for Supplemental Information before starting installation. This Blower Kit may be used with gas replaces.
CLICK
High Quality Aftermarket Fireplace Blowers & Fans
1-800-466-4045
Check the contents of the carton.
Make sure nothing was damaged in shipment.
Do NOT install a damaged blower kit!
Blower Kit Parts
Step 1: Turn Off Fireplace and allow it to cool
down. Disconnect from 120V Power. Shut off
the Gas supply. Remove the louver which cov-
ers the lower vent space below the rebox.
Lay cord set out in a straight line, with the
3-Prong Power Plug furthest away from the
replace.
Figure: 1
Step 2: Push the Green Ground Wire disconnect onto
the ground tab on the end of fan. (Figure: 1)
Connect white and black wires of the cord set to ei-
ther of the two spade terminals attached to the motor.
Push disconnects onto metal tabs.
(Figure: 1)
CLICK
CLICK
NOTE: Diagrams and Illustrations NOT to Scale
Page 1 of 5
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK!
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set;
Preventing it from making contact with moving or hot objects.
Description
Qty.
Fan
Thermodisc / Heat Sensor
Variable Speed Control
Cord Set
Wire Nut
Mounting Bracket for Fan
Dampening Pad, Velcro Strip
Crimp Butt Connector for Wire
1
1
1
1
1
2
1
2
Face Plate for Wall
Installation Instructions
(Downloadable)
1
1
Question and Answer IconNeed help?

Do you have a question about the My Fireplace Blower FBK-250 and is the answer not in the manual?

Summary

Blower Kit Components and Preparation

Critical Safety Warning

Highlights risks of fire and electrical shock during installation.

Blower Kit Parts Verification

Lists all components to check for damage or missing items.

Step 1: Preparing for Installation

Shutting off power/gas and clearing the vent space.

Blower Assembly and Wiring

Steps 2 & 3: Mounting the Blower Fan

Connecting ground wire, mounting fan assembly using velcro.

Step 4: Installing the Thermodisc

Placing the magnetic thermodisc for activation.

Speed Control and Final Wiring

Step 5: Positioning Speed Control

How to place and set the variable speed control.

Blower Wiring and Activation Logic

Explains wiring diagram and conditions for blower operation.

Advanced Installation and Final Checks

Step 6: Final Power Connection

Plugging the blower kit into the main power source.

Optional Wall-Mounted Control

Guide for integrating the speed control into a wall switch.

Restoring Power and Gas

Steps for safely turning the appliance back on.

Wiring Connections and Speed Control Setup

Connecting Wires to Thermodisc

Stripping and connecting black wires using crimp connectors.

Speed Control Wiring Detail

Connecting speed control wires to existing switch wiring.

Mounting the Variable Speed Control

Removing and reattaching the speed control knob and faceplate.

Overview

This document provides installation instructions for the FBK-250 Blower Kit with Cord Set, designed for use with gas fireplaces. It emphasizes safety precautions, including turning off gas and electrical power before installation, and ensuring proper containment of excess wiring to prevent contact with moving or hot objects. The kit is tested and safe when installed according to these instructions, but users are advised to consult their fireplace's Owner's Installation Manual for supplemental information.

Function Description:

The FBK-250 Blower Kit is an aftermarket accessory designed to improve the heating efficiency of gas fireplaces by circulating air. It includes a fan, a thermodisc/heat sensor, a variable speed control, and a cord set. The system works by drawing in room air from the bottom vent space, circulating it around the hot firebox, and then expelling heated air back into the room through the top vent. The thermodisc/heat sensor automatically activates the blower when the fireplace reaches approximately 120°F and turns it off when the temperature drops below 90°F, ensuring efficient operation without manual intervention. The variable speed control allows users to adjust the fan's speed.

Important Technical Specifications:

  • Power: Operates on 120V/60Hz power.
  • Activation Temperature: Thermodisc/Heat Sensor activates at approximately 120°F.
  • Deactivation Temperature: Thermodisc/Heat Sensor deactivates below 90°F.
  • Components:
    • Fan: 1
    • Thermodisc / Heat Sensor: 1
    • Variable Speed Control: 1
    • Cord Set: 1
    • Wire Nut: 2
    • Mounting Bracket for Fan: 1
    • Dampening Pad, Velcro Strip: 2
    • Crimp Butt Connector for Wire: 1
    • Face Plate for Wall: 1
    • Installation Instructions (Downloadable): 1

Usage Features:

  • Automatic Operation: The thermodisc/heat sensor ensures the blower turns on and off automatically based on fireplace temperature, providing hands-free operation.
  • Variable Speed Control: Users can adjust the fan's speed using the variable speed control dial. The control must be in the "ON" position for the blower to operate. Turning the dial left will click it off, and turning it right will reduce speed.
  • Flexible Installation Options:
    • Under Firebox Installation: The variable speed control can be placed on the floor of the lower vent space near the front.
    • Wall Mounted Variable Speed Control Option: For fireplaces with an existing wall switch dedicated to the 120V power supply in the vent space, the variable speed control can replace this switch. This involves cutting and crimping wires to integrate the control into the existing electrical setup, and securing it with a face plate.
  • Easy Fan Mounting: The fan assembly slides into the bottom vent space, with mounting tabs fitting into notches in the mounting bracket. Velcro strips on the dampening pads help secure the fan and reduce vibration.
  • Clear Airflow Direction: The fan's rectangular air exit port should face upwards to ensure proper heated air circulation.

Maintenance Features:

  • Pre-Installation Cleaning: Before installing the blower kit, it is recommended to clean the fireplace's vent space to remove drywall dust or other fragments. This prevents potential bearing or motor damage, which is not covered by the warranty.
  • Damage Inspection: Users are instructed to check the contents of the carton upon receipt and not to install a damaged blower kit.
  • Proper Grounding: The installation instructions emphasize the importance of proper electrical grounding in accordance with local codes and national electrical codes (CSA C22.1 in Canada, ANSI Z223.1-1988 and ANSI/NFPA 70-1987 in the USA).
  • Wire Management: Excess wire from the cord set must be contained to prevent contact with moving or hot objects, which is crucial for safety and longevity of the device.

The manual provides detailed, step-by-step instructions with accompanying diagrams to guide users through the installation process, including connecting wires, positioning components, and securing the blower. It also includes contact information for My Fireplace Blower for support.

My Fireplace Blower FBK-250 Specifications

General IconGeneral
BrandMy Fireplace Blower
ModelFBK-250
CategoryBlower
LanguageEnglish