section 7 ~ myerson DuraFlex partial
injection procedure
The following procedure outlines the steps necessary to create
myerson DuraFlex Partials with the myerson Flexpress™ Digital
Injection System.
1. Evaluate the model for major undercuts and block out the
undercuts. Due to the exibility and adjustability of the material,
very little if any blocking out will be needed.
2. Paint the model with myerson Thermoplastic Model Separator
MS-0200.
7
section 6 ~
processing using the
“Re-run Last Profile”
1. From the main menu use the UP or DOWN buttons until the cursor
is to the left of “Rerun Last Prole” then press the enter button.
2. The display will show the prole name and prole settings of the
last injection. If this is not the prole you wish to run, press the
LEFT arrow button to return to the main menu.
3. The myerson Flexpress™ is now ready to process your case.
See steps 5-13 of Section 5 for a complete injection.
12. Press the EXTEND/RETRACT button again to retract the piston.
13. The myerson Flexpress™ is now ready to process another case.
Repeat steps 1-9 for your next injection.