TROUBLESHOOTING
SYMPTOM: UNIT WILL NOT TURN ON:
PROBLEM: Not plugged in.
SOLUTION: Plug machine in proper outlet.
PROBLEM: Circuit breaker has popped.
SOLUTION: Reset circuit breaker. Make sure no other items are running on the same circuit as machine. Outlet
must be a 15-amp circuit.
PROBLEM: Wire from power cord has become disconnected from terminal block.
SOLUTION: Reattach wire to terminal block.
SYMPTOM: PUMP IS NOT RUNNING PROPERLY:
PROBLEM: Quick disconnects are not completely locked together.
SOLUTION: Snap quick disconnects firmly together.
PROBLEM: The solution tank is empty.
SOLUTION: Fill the solution tank up with a premixed detergent.
PROBLEM: Jet on upholstery tool is clogged.
SOLUTION: Clean jet with soft wire brush or remove jet and flush clean.
PROBLEM: Filters are clogged.
SOLUTION: Remove filters and rinse clean with water.
PROBLEM: Heater is blocked with hard water deposits.
SOLUTION: Flush out heaters with system maintainers. If they are still blocked, replace heaters.
PROBLEM: Brass check valve is stuck.
SOLUTION: Replace with new check valve.
PROBLEM: Pump wire has become disconnected.
SOLUTION: Reconnect wire.
PROBLEM: Switch on switch plate is bad.
SOLUTION: Replace switch.
PROBLEM: Pump motor brushes are worn out.
SOLUTION: Replace pump.
SYMPTOM: HEATER IS NOT WORKING PROPERLY:
PROBLEM: The back up sensor, mounted on the heater has popped.
SOLUTION: Reset sensor by pushing in button.
PROBLEM: The automatic sensor mounted to the heater has worn out.
SOLUTION: Replace with a new automatic sensor.
PROBLEM: Heater wire has become disconnected.
SOLUTION: Reconnect wire.