IDLE
CURRENT
ADJUSTMENT
1.
Connect
DMM
across
P-401
(+)
and
P-408
(-),
adjust
VR-447
for
reading
of
5mV
+/-
0.5mV
DC.(without
a
load
across
the
output
terminals.)
2.
Repeat,
using
P-402
(+)
and
P-404
(-),
adjust
VR-448.
3.
Repeat
above
procedures
for
each
amplifier
module.
B.
FINAL
ADJUSTMENT
1.
Leave
power
on
minimum
5
minutes.
2.
Repeat
idle
current
adjustments.