0x100A
INT8U
reportable
Hysterersis setting, range is 5-20, unit is 0.1ºC, default value
is 5
Hysterersis
0x1224
0x2001
INT8U,
reportable
0 means disabled, default is 45
AlarmAirTempOverValue
Room temp alarm threshold, range is 0.20-60, unit is 1ºC,
0x1224
Command supported:
Command Description
0x0000
Setpoint Raise/Lower
Increase or decrease the set temperature according to current mode, unit is
0.1ºC
5.2.5 Simple Meter-0x0702 (Server)
Attributes supported:
Attribute
Type Description
0x0000
unsigned48 ,
read-only,
reportable
Indicates the current amount of electrical energy delivered to the load.
CurrentSummationDelivered
0x0200
bitmap8 ,
read-only
Status
Flags indicating current device status, always is 0x00
0x0300
enum8 ,
read-only
UnitOfMeasure
The unit of metering data, this is always kWh(0x00)
0x0301
Int24U,
read-only
Multiplier
0x0302
Int24U,
read-only
Divisor
0x0303
map8 ,
read-only
The decimal point on the left and right sides of the data, this is always 0x00
SummationFormatting
0x2002
ENUM8
reportable
Value=1: away
Value=0: not away (default)
Away Mode Set:
0x1224
0x100B
ENUM8
reportable
0, disable Display Auto Off function
DisplayAutoOffEnable
1, enable Display Auto Off function
0x1224
0x0000
bitmap32 ,
read-only
MeasurementType
Indicates the physical entities that this devices is able to measure. Supports
only bit0: Active measurement (AC)
0x0505
int16U ,
read-only,
reportable
RMSVoltage
Single phase valid voltage, unit is V
0x0508
int16U ,
reportable,
read-only
Single phase valid current, unit is A
RMSCurrent
5.2.6 Electrical Measurement-0x0b04(Server)
Attributes supported:
Attribute
Type Description
0x0306
bitmap8,
read-only
Metering data type, this is always Electric Metering (0x00)
MeteringDeviceType