Namron ZIGBEE 16A - Electrical Measurement Proprietary Attributes; Over Current Setting; Alarm and Time Clusters; Alarm Cluster

Namron ZIGBEE 16A
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0x050B
int16S ,
reportable
read-only
Single phase valid power, unit is W
ActivePower
0x0600
int16U,
read-only
ACVoltageMultiplier
0x0601
int16U,
read-only
ACVoltageDivisor
Used together with above attributes, the real displayed voltage =
RMSVoltage* ACVoltageMultiplier
/ ACVoltageDivisor
0x0602
int16U,
read-only
ACCurrentMultiplier
0x0603
int16U,
read-only
ACCurrentDivisor
/ ACCurrentDivisor
Used together with above attributes, the real displayed current = RMSCurrent
* ACCurrentMultiplier
0x0800 int16U,
Specifies which configurable alarms may be generated, only
Bit1: Current Overload is set, if set=0, then ACCurrentOverload=0, over
current will not be detected
ACAlarmsMask
0x0802
int16S ,
reportable
read-only
ACCurrentOverload
Alarms when the current is over a certain value, 0, 10-16, unit is A, for the
unit please refer to RMSCurrent, ACCurrentMultiplier, ACCurrent Divisor
Proprietary Attributes:
Attribute
0x0000
Type
Int8u,
reportable
Manufacturer code
0x1224
Description
OverCurrent
Over current value set by the user, range is 0, 10-16,
ACCurrentOverload will change spontaneously if this
value is modified.
5.2.7 Alarm-0x0009(Server)
The Alarm Server cluster can generate the following commands
Please set a valid value for ACAlarmsMask of Electrical Measurement.
The Time cluster is a general cluster for time it is based on a UTC time in seconds since 0 hrs 0 mins 0 sec on
1st January 2000. Refer to [Z2] for ZigBee specification of the time cluster.
If the device has bound TIME cluster, then the device will acquire the value of Local
Time (0x0007)
spontaneously.
5.2.8 Time-0x000A(server)
The metering device will use this clusters as a client – provided that a suitable Time Server is available on the
network (most likely on the Gateway/concentrator)
0x00
Room air temperature over heat, not alarm code
CmdID Description
CmdID Description
0x00
Alarm:
The alarm code of Electrical Measurement is 0,
Proprietary command, Manufacturer code=0x1224