AA34-300 Environmental Qualification Form
Rev: 1.01 May 21, 2010 Page 2 of 2
ENG-FORM: 521-0102.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
Conditions DO-160C Section Description of Conducted Tests
Fluids Susceptibility 11.0 Category X, no test performed
Sand and Dust 12.0 Category X, no test performed
Fungus Resistance 13.0 Category X, no test performed
Salt Spray 14.0 Category X, no test performed
Magnetic Effect 15.0 Class A
Power input 16.0 Category B
Equipment met requirements for
Emergency Electrical System Operation per
DO-160C subparagraph 16.5.2.1 b (3)
Voltage Spike 17.0 Category A
Audio Frequency Susceptibility 18.0 Category B
Induced Signal Susceptibility 19.0 Category A
Radio Frequency Susceptibility 20.0
Change No. 3
Category T
Radio Frequency Emission 21.0 Category A
Lightning Induced Transient
Susceptibility
22.0 Category X, no test performed
Lightning Direct Effects test 23.0 Category X, no test performed
Icing 24.0 Category X, no test performed
REMARKS
• DO-160C, Sections 4 to 8, and 15 to 21 tests were conducted at Northern Airborne Technology
Ltd. (NAT) in Kelowna, BC on AA34-300.
• DO-160C, Sections 16, 17, and 18 Power Input tests were conducted using the +28Vdc and
+14Vdc Power Inputs.
End of Environmental Qualification Form