EasyManuals Logo

National Instruments MXI-Express Gen-3 x16 User Manual

National Instruments MXI-Express Gen-3 x16
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Power Requirements
Power Rail Typical Current Maximum Current
+3.3 V 1.688 A 1.9 A
+3.3 V
AUX
40 mA 146 mA
+12 V 731 mA 1.6 A
Environment
Maximum altitude 2,000 m
Pollution Degree 2
Indoor use only.
Operating Environment
Ambient temperature range 0 °C to 55 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2.)
Relative humidity range 10% to 90%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
Storage Environment
Ambient temperature range -20 °C to 70 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2.)
Relative humidity range 5% to 95%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
Note Clean the PCIe-8398 with a soft nonmetallic brush. Make sure that the device
is completely dry and free from contaminants before returning it to service.
Safety
This product is designed to meet the requirements of the following standards of safety for
information technology equipment:
IEC 61010-1, EN 61010-1
CAN/CSA-C22.2 No. 61010-1
Note For UL and other safety certifications, refer to the product label or the Online
Product Certification section.
24 | ni.com | MXI-Express Gen-3 x16 User Manual

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments MXI-Express Gen-3 x16 and is the answer not in the manual?

National Instruments MXI-Express Gen-3 x16 Specifications

General IconGeneral
BrandNational Instruments
ModelMXI-Express Gen-3 x16
CategoryController
LanguageEnglish

Related product manuals