EasyManuals Logo

National Instruments NI 6225 User Manual

National Instruments NI 6225
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #335 background imageLoading...
Page #335 background image
Appendix B Timing Diagrams
M Series User Manual B-12 ni.com
Figure B-11. Sample Clock Timebase Timing and the Analog Input Timing Engine
Table B-5. Convert Clock Timebase Timing
Time Description Line Min (ns) Max (ns)
t
13
Delay to Selected Start PFI 3.4 8.8
RTSI 3.3 8.5
STAR 2.7 5.7
t
14
Selected Start Setup Time
(to Sync Convert Clock Timebase)
— 1.5 —
t
15
Selected Start Hold Time
(to Sync Convert Clock Timebase)
— 0 —
t
16
Sync Convert Clock Timebase to Start — 0.9 2.4
t
17
Start to POUT PFI 1.1 3.1
RTSI 1.1 2.7
Start
Terminal
Selected Reference Trigger Reference Trigger
Te r m in al
Terminal
Selected Sample Clock
Te r m in al
Terminal
Te r m in al
Selected Start
RTSI
Te r m in al
Terminal
Terminal
Selected Pause Trigger
SI
Counter
Block
SI2
Counter
Block
SI_TC
Sample Clock Timebase
Sync Sample Clock Timebase
Convert Clock Timebase
Sync Convert Clock Timebase
SI Start
Pause Trigger
p_AI_Convert
Start
1
_i
SI2_TC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments NI 6225 and is the answer not in the manual?

National Instruments NI 6225 Specifications

General IconGeneral
BrandNational Instruments
ModelNI 6225
CategoryMedia Converter
LanguageEnglish

Related product manuals