EasyManua.ls Logo

Navien NaviCirc - Page 68

Navien NaviCirc
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
68
* A Taco 008-BC6 or Grundfos 15-42 BUC7 (or equivalent) circulation pump
is recommended for use with the NCB-H boiler and DHW recirculation
systems.
* When using the external recirculation mode, observe the following
maximum recirculation pipe lengths including ttings (
3
/
4
pipe is
recommended). Lengths in excess of these limits will require a larger
recirculation pump.
Maximum Pipe Lengths
Pipe Diameter
1
/
2
"
3
/
4
"
Maximum Pipe Length 100 ft (30 m) 400 ft (120 m)
Note
To use HotButton mode, install a HotButton and
recirculation pump.
Install the NaviCirc recirculation valve to the faucet
furthest from the NCB-H boiler.
If installed in close proximity to the boiler, faucets
further down the supply line will take longer to
receive hot water.

Related product manuals