* A Taco 008-BC6 or Grundfos 15-42 BUC7 (or equivalent) circulation pump
is recommended for use with the NFC-H boiler and DHW recirculation
systems.
* When using the external recirculation mode, observe the following
maximum recirculation pipe lengths including ttings (
3
/
4
pipe is
recommended). Lengths in excess of these limits will require a larger
recirculation pump.
Maximum Pipe Lengths
Pipe Diameter
1
/
2
"
3
/
4
"
Maximum Pipe Length 100 ft (30 m) 400 ft (120 m)
Note
Install the NaviCirc recirculation valve on the faucet
furthest from the NFC-H boiler.
If installed in close proximity to the boiler, faucets
further down the supply line will take longer to
receive hot water.