These appliances are for use with natural gas or LPG.
(An LPG conversion kit is included with the boiler.)
Ɣ
Type: B23-B33-B53-C13-C33-C43-C53-C63-C83
Gas Model GC Number
Natural Gas
NCB-24LDWE
NCB-28LDWE
NCB-34LDWE
NCB-40LDWE
47-709-01
47-709-02
47-709-03
47-709-04
LPG
NCB-24LDWE
NCB-28LDWE
NCB-34LDWE
NCB-40LDWE
47-709-05
47-709-06
47-709-07
47-709-08
Keep this manual near this boiler for future r eference
whenever maintenance or service is required.
Installation &
Operation
Manual
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may
result, causing property damage or personal injury.
Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Ɣ
Do not try to light any appliances.
Ɣ
Do not touch any electrical switch; do not use any phone in your building.
Ɣ
Immediately call the National Gas Emergency Helpline on (Freephone) 0800 111999 or your gas
supplier from a neighbour’s phone. Follow the instructions received.
Installation and service must be performed by a Gas Safe registered installer, service agency or
the gas supplier.
Condensing Combi Boiler

Table of Contents

Other manuals for Navien NCB-34LDWE

Questions and Answers

  • J
    justinjohnsonAug 9, 2025
    Why is my Navien NCB-34LDWE space heating not working?
    • J
      Jason BrownAug 10, 2025
      If your Navien Boiler's space heating isn't working, first ensure the temperature setting isn't too low. Then, confirm the system has power and isn't in standby mode by checking the power connection and pressing the Power button. Note that the heating side won't function when the unit is heating domestic hot water (DHW). Finally, inspect and clean the filters on the heating side.
  • J
    Joshua WallsAug 16, 2025
    How to fix not hot enough water from Navien Boiler?
    • G
      gregoryandersonAug 17, 2025
      If the water from your Navien Boiler's hot water tap is not hot enough, begin by checking the boiler’s temperature setting. Also, check for cross plumbing between the cold and hot water lines.
  • J
    jesse19Aug 25, 2025
    What to do if Navien NCB-34LDWE hot water is too hot?
    • L
      lewisericAug 25, 2025
      If the water from your Navien Boiler's hot water tap is too hot, check the boiler’s temperature setting.
  • V
    vcontrerasSep 1, 2025
    How to fix no water coming out of Navien NCB-34LDWE?
    • J
      Jessica MeyersSep 1, 2025
      If no water comes out when you open the hot water tap connected to your Navien Boiler, make sure that the shut–off valves on the hot and cold pipes are open.

Summary

Safety Information

General Safety Warnings

Descriptions of DANGER, WARNING, CAUTION symbols and general safety advice.

Flammable Materials and Gas Safety

Covers handling flammable liquids and gas leak procedures.

Boiler Operation Safety

Covers safe operation, flue systems, and electrical safety.

Water Temperature and Burn Prevention

Covers hot water safety and scalding risks.

Boiler Operating Modes

Boiler Installation Procedure

Gas Supply and Flue System

Gas Supply Connection Procedure

Steps for connecting the boiler to the gas supply.

DIP Switch Settings

Electrical Connections

Power Supply and Control Device Connections

Instructions for connecting power and control devices.

Installation Checklist

Installation Checklist

A list of checks to perform after installation.

Boiler Operation

Setting Boiler Parameters

Detailed configuration of various boiler operating parameters.

Boiler Maintenance

Detailed Service Procedures

In-depth steps for servicing the boiler.

Appendices

Gas Conversion Procedure

Steps to convert the boiler for LPG.

Navien NCB-34LDWE Specifications

General IconGeneral
CategoryBoiler
TypeCombi Boiler
BrandNavien
ModelNCB-34LDWE
Fuel TypeNatural Gas / Propane
Max. Input (BTU/hr)34, 000
Input (BTU/h)34, 000
Voltage120 V
Weight80 lbs
Efficiency95%
Water Connection Size3/4 in.
Vent TypePVC/CPVC
Vent Size2 in. / 3 in.
Gas Connection Size3/4" NPT
Dimensions (H x W x D)30.5 in. x 17.75 in. x 12.75 in.