112
SETTING
7 Pressing the END button will exit the “EDIT” mode.
Select “START” and press ENTER to execute the program.
• The “*EXECUTING NO. XX*” will appear during program
execution. When the program is finished, the “*SEQUENCER
END*” message will appear for about five seconds.
NOTE: To cancel the program, hold down the CTL button then
press END. The “*SEQUENCER MANUAL END*” will appear for
about five seconds.
8 To end this mode, press the END button.
• Whenever the END button is pressed, the menus will sequence
in this order:
“SEQUENCER” screen (No highlighted line) → “ADJUST”
menu → Source screen
• If the “RETURN USER MODE?” menu appears, use the
CURSOR or button to select either “YES” or “NO” and
then press ENTER. This will exit the ADJUST mode.
Items to select
• YES ......... When you try to enter the ADJUST mode the next
time, you will need to re-enter your passcode.
• NO ........... When you try to enter the ADJUST mode the next
time, you will not need to re-enter your passcode.
RETURN USER MODE?
YES NO
OPTION - SEQUENCER -
P01
NO
01
02
03
04
05
06
07
08
09
10
INPUT
M-10
M-02
M-01
WAIT
M-01
WAIT
LOOP
M-02
P-OFF
P-ON
S-01
S-02
S-02
S-01
03 COUNT 05
S-02
TIME
12:00:00
14:00:00
00:10:00
00:20:00
15:50:00
18:00:00
09:00:00
SMTWTFS
XOOOOOX
XOOOOOX
XOOOOOX
XOOOOOX
XOOOOOX
XOOOOOX
XOOOOOX
START EDIT