2
EN
Quick Install sheet | Invexs 170 Readers Mifare Nedap dual technology readers
Version 12.0
backside of the front. After making the connections, replace the front and tighten up the two
screws at the bottom of the Invexs.
4. Connections
Invexs is not hot-swappable, so when making or changing connections power must be switched
Off.
Cable shield must be connected to Power GND of Convexs (A2) and GND of
external device (or metal case).
If connected to a 120kHz RF device (AEOS Nedap reader AEpack or XS device) the
power is supplied via the Convexs adapters (AX1014 for AEpacks, AB350 for XS
devices). Existing antenna cabling can then be reused for connecting the
ConveXS.
UL*,NA* and BEEP are Open Collector to GND.
If the Convexs adapters are used, the original UL and NA signals are
converted to the UL* and NA*.
5. LED Indicators Inside
There are two LEDs available: Blue for Status (of application), Green for Identification (both
visible through two small holes at the back side).
6. LED Indicators Front
At the front a three colour LED is positioned at the middle of the Invexs
Depending on the used configuration the function of these LEDs can differ:
Green LED: Card is been authorised (UL LED)
Red LED: Card is not authorised (NA LED), controller is stand-by
Blue LED:
Blinks fast; No configuration is available at this Invexs (present Configuration
card or load Configuration first).
Continuously ON; Determined by configuration: E.g. Reader stand-by.
(Blue LED is activated if UL is OFF and NA is more than 1 sec OFF.)
Invexs
Function
1
Power /
XSMOD
Power in (12-30VDC) /
XS modulator (120kHz)
2
POWER GND/Shield
Power Ground
3
A (-)
RS485
4
B (+)
RS485
5
D0
Wiegand Data 0
6
D1
Wiegand Data 1
7
BEEP
Beep input
8
UL*
UL LED input
9
GND
LED Common Ground
10
NA*
NA LED input
R
GND
UL*/NA* / BEEP
1
10
1
10
5
6
Invexs with display
Invexs without display
ID (green)
Blinking
Card detected
ST: STATUS (blue)
Slow blinking
Application running (operating)
Fast blinking
Downloading or error during
loading
2 short flashes
Application present but not active
3 short flashes
No application present