EasyManua.ls Logo

Nedap Invexs MD190 User Manual

Nedap Invexs MD190
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
11 April 2011 Version 9
This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys
no licence under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifica-
tions and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in
whole or in part, without the written consent of the publisher.
© Nedap N.V., IDEAS P.O. Box 103 NL-7140 AC GROENLO The Netherlands
Page 1 of 21
Nedap Readers Convexs & Invexs
Installation Guide and User Manual
®
1
2
3
4
5
6
7
8
9
C
0
E
1
2
3
4
5
6
7
8
9
C
0
E

Table of Contents

Other manuals for Nedap Invexs MD190

Question and Answer IconNeed help?

Do you have a question about the Nedap Invexs MD190 and is the answer not in the manual?

Nedap Invexs MD190 Specifications

General IconGeneral
Frequency13.56 MHz
Power Supply12-24 V DC
Operating Voltage12-24 V DC
TechnologyRFID
Supported CardsDESFire
InterfaceWiegand, RS485
Housing MaterialABS plastic
Weight200 g

Summary

Convexs/Invexs Protocols

RS485NR Protocol Details

Details bi-directional, encrypted communication using RS485NR for AEOS integration.

RF Output Options

Explains how to connect readers via RF to AEpacks and Nedap XS readers.

Wiegand Protocol Usage

Covers connecting readers to third-party systems using various Wiegand protocols.

Serial RS485 (RS485 Ascii) Details

Describes serial connection setup for third-party systems using RS485 Ascii.

Configuring the Convexs/Invexs Reader

Using a Configuration Card

Details how to deploy reader settings using a physical configuration card.

Nedap Reader Configuration File

Describes loading configuration files via AEmon or directly via AEreco.

Wiegand Protocol Data Definitions

Wiegand 26-bit Format

Details the data definition, format, and parity for Wiegand 26-bit protocol.

Convexs/Invexs Connections

Convexs Reader Wiring Guide

Details pin assignments for Convexs readers, including power, RS485, and Wiegand connections.

Invexs 170 Reader Wiring Guide

Details pin assignments for Invexs 170 readers, covering power, RS485, and Wiegand.

Invexs 190 Reader Wiring Guide

Provides wiring colors and functions for Invexs 190 readers.

Related product manuals