Page 9
-↑ +↓
P102
Exit 1 reset time (0 - 60) min F[0]
If F[0] the function is not on.
-↑ +↓
P103
Exit 1 Wind sensor function (0 - 2) F[0]. Set the action when active as
follows:
0=none
1=open
2=close
-↑ +↓
P104
Exit 1 Rain sensor function (1 - 2) F[2]. Set the action when the input is
active, as follows:
1=open
2=close
-↑ +↓
P105
Exit 1 Timer function F[0]. Set the action when active as follows:
0=none
1=open
2=close
-↑ +↓
P106
Exit 1 Aeration time (1-60)min F[10].
-↑ +↓
P107
Exit 1 Single manual command functioning mode F[0]:
0=half-automatic mode
1=dead-man mode, sensors and remote controls enabled
2= dead-man mode, sensors and remote controls disabled
-↑ +↓
P201 Exit 2 Work time (10 - 240) s F[60]
-↑ +↓
P202
Exit 2 Reset time (0 - 60)min F[0]
If F[0] the function is not on.
-↑ +↓
P203
Exit 2 Wind sensor function (0 - 2) F[0]. Set the action when active as
follows:
0=none
1=open
2=close
-↑ +↓
P204
Exit 2 Rain sensor function (1 - 2) F[2]. Set the action when the input is
active, as follows:
0=none
1=open
2=close
Page 10
-↑ +↓
P205
Exit 2 Timer function F[0]. Set the action when active as follows:
0=none
1=open
2=close
-↑ +↓
P206
Exit 2 Aeration time (1-60)min F[10].
-↑ +↓
P207
Exit 2 Single manual command functioning mode:
0=half-automatic mode
1=dead-man mode, sensors and remote controls enabled
2= dead-man mode, sensors and remote controls disabled
-↑ +↓
P301 Exit 3 Work time (10 - 240) s F[60]
-↑ +↓
P302
Exit 3 Reset time (0 - 60)min F[0]
If F[0] the function is not on.
-↑ +↓
P303
Exit 3 Wind sensor function (0 - 2) F[0]. Set the action when active as
follows:
0=none
1=open
2=close
-↑ +↓
P304
Exit 3 Rain sensor function (1 - 2) F[2]. Set the action when the input is
active, as follows:
0=none
1=open
2=close
-↑ +↓
P305
Exit 3 Timer function F[0]. Set the action when active as follows:
0=none
1=open
2=close
-↑ +↓
P306 Exit 3 Aeration time (1-60)min F[10].
-↑ +↓
P307
Exit 3 Single manual command functioning mode:
0=half-automatic mode
1=dead-man mode, sensors and remote controls enabled
2= dead-man mode, sensors and remote controls disabled