NOTES FOR CLASS I DIVISION 2 INSTALLATIONS:
WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT
WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE
OF IGNITABLE CONCENTRATIONS.
NOTE FOR CLASS I DIVISION 2 INSTALLATIONS (RACK MOUNT VERSIONS):
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D
HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY
FOR RACK MOUNT INSTALLATION ON A TYPE 1 ENCLOSURE WITH
PROVISIONS FOR CLASS I DIVISION 2 WIRING METHODS
TEMPERATURE CODE: T6 (T4A FOR N2800 OPTION)
NOTE FOR CLASS I DIVISION 2 INSTALLATIONS (NP300 UNITS):
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D
HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY
FOR USE ON A FLAT SURFACE OF A TYPE 1 ENCLOSURE WITH
PROVISIONS FOR CLASS I DIVISION 2 WIRING METHODS
TEMPERATURE CODE: T6 (T4A FOR N2800 OPTION)
WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENTS
MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2
NOTE FOR CLASS I DIVISION 2 INSTALLATIONS (PANEL MOUNT VERSIONS):
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D, CLASS II
DIVISION 2, GROUPS F AND G, CLASS III HAZARDOUS LOCATIONS, OR
NONHAZARDOUS LOCATIONS ONLY
FOR USE ON A FLAT SURFACE OF A TYPE 1, 4, 4X, OR 12 ENCLOSURE WITH
PROVISIONS FOR CLASS I DIVISION 2 WIRING METHODS
TEMPERATURE CODE: T6 (T4A FOR N2800 OPTION)