16
Unplug power plug! Turn drip tray over. Take
outtheinjectortool.Pullcleaningneedleout
ofinjectortool.Keep needle out of reach of
children!
Remove injector only on cold machine! Turn
injectortoolanti-clockwise.Removeinjector.
Do not leave injector unattended! Keep
injector out of reach of children!
Insertcleaningneedleintoinjectortounclog
it. If not possible, prepare a descaling solution
with one sachet and 0.5 L drinking water. Put
injectorindescalingsolution.
Check whether both o-rings are intact and are
intherightplaceontheinjector.Putinjector
ontoinjectortool.
Insertinjectorfrombelowintoopeningof
machine.Supportinjectorwithhand.Rotate
injectorclockwiseuntilitts.Followinstructions
in “3. BEVERAGE EXAMPLES“ on page 6.
Removecapsuleholder.Pushinjectortoolover
injector.
9. TROUBLESHOOTING
9.2 NO LIQUID COMES OUT – CAPSULE / INJECTOR BLOCKED?
6
7
5
9
10