EasyManua.ls Logo

nest Learning - Heat Pump with Aux & Emergency Heat

nest Learning
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 Stage Heat Pump with Aux heat and Emergency Heat
Label:
Function:
Y1
Compressor Relay (Stage 1)
Y2
Compressor Relay (Stage 2), 2nd-speed fan
relay
G
Fan Relay*
O/B
Heat Pump Changeover Valve
Rc
24VAC power from cooling transformer
W1
Heat Relay (Stage 1)
W2/AUX
Heat Relay (Stage 2) /Auxiliary Heat Relay
C
24VAC Common Wire †
*
Star:W3, E, HUM/DHUM, 3rd-speed fan relay
Rh
24VAC power from heating transformer ‡
2 Stage Heat Pump
Label:
Function:
Y1
Compressor Relay (Stage 1)
Y2
Compressor Relay (Stage 2), 2nd-speed fan
relay
G
Fan Relay*
O/B
Heat Pump Changeover Valve
Rc
24VAC power from cooling transformer
W1
Heat Relay (Stage 1)
W2/AUX
Heat Relay (Stage 2) / Auxiliary Heat Relay
C
24VAC Common Wire †
*
Star: W3, E, HUM/DHUM, 3rd-speed fan relay
Rh
24VAC power from heating transformer ‡
13