EasyManua.ls Logo

nest Learning - Supported Wiring; Nest Thermostat Connector Definitions

nest Learning
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supported Wiring
Nest Thermostat Connectors
Heat pump connectors:
Y1
Stage 1 compressor relay
Y1
Stage 1 compressor relay
Y2
Stage 2 compressor relay, 2nd-speed fan
relay
Y2
Stage 2 compressor relay
G
Fan relay
G
Fan relay
O/B
Not used
O/B
Changeover valve relay
Rc
24VAC power from cooling transformer*
Rc
Not used
W1
Stage 1 heat relay
W1
Stage 1 heat relay
W2/AUX
Stage 2 heat relay
W2/AUX
Auxiliary heat relay
C
24VAC common wire
C
24VAC common wire.
Star *
Stage 3 heat (W3), humidification (HUM), or
dehumidification (DEHUM), 3rd-speed fan
relay
Star *
Emergency heat (E), humidification (HUM), or
dehumidification (DEHUM)
Rh
24VAC power from heating transformer*
Rh
24VAC power from transformer*
* No jumper wires required. You don’t need to hang on to any old jumper wires going from Rh (sometimes just called R) to Rc. Nest will
automatically jump these two connectors.