If your system has… Then…
No network connection and is in a
MetroCluster IP configuration
a.
Press
n when prompted to restore the backup configuration.
b. Reboot the system when prompted by the system.
c. Wait for the iSCSI storage connections to connect.
You can proceed after you see the following messages:
date-and-time [node-
name:iscsi.session.stateChanged:notice]:
iSCSI session state is changed to Connected
for the target iSCSI-target (type:
dr_auxiliary, address: ip-address).
date-and-time [node-
name:iscsi.session.stateChanged:notice]:
iSCSI session state is changed to Connected
for the target iSCSI-target (type:
dr_partner, address: ip-address).
date-and-time [node-
name:iscsi.session.stateChanged:notice]:
iSCSI session state is changed to Connected
for the target iSCSI-target (type:
dr_auxiliary, address: ip-address).
date-and-time [node-
name:iscsi.session.stateChanged:notice]:
iSCSI session state is changed to Connected
for the target iSCSI-target (type:
dr_partner, address: ip-address).
d. Select the Update flash from backup config (sync flash) option
from the displayed menu.
If you are prompted to continue with the update, press
y.
4. Ensure that the environmental variables are set as expected:
a. Take the impaired controller to the LOADER prompt.
b. Check the environment variable settings with the printenv command.
c. If an environment variable is not set as expected, modify it with the setenvenvironment_variable_name
changed_value command.
d. Save your changes using the saveenv command.
5. The next depends on your system configuration:
If your system has onboard keymanager, NSE or NVE configured, go to
Post boot media replacement
steps for OKM, NSE, and NVE
1071