1. From the LOADER prompt, reboot the node: bye
2. If your system is configured to support 10 GbE cluster interconnect and data connections on 40 GbE NICs
or onboard ports, convert these ports to 10 GbE connections by using the nicadmin convert command from
Maintenance mode.
Be sure to exit Maintenance mode after completing the conversion.
3.
Return the node to normal operation:
storage failover giveback -ofnode
impaired_node_name
4.
If automatic giveback was disabled, reenable it:
storage failover modify -node local -auto
-giveback true
Step 4: Return the failed part to NetApp
After you replace the part, you can return the failed part to NetApp, as described in the
RMA instructions shipped with the kit. Contact technical support at
NetApp Support, 888-
463-8277 (North America), 00-800-44-638277 (Europe), or +800-800-80-800
(Asia/Pacific) if you need the RMA number or additional help with the replacement
procedure.
Replace an LED USB module - AFF A900
The LED USB module provides connectivity to console ports and system status.
Replacement of this module does not require tools and does not interrupt service.
Step 1: Replace the LED USB module
Steps
1. Remove the old LED USB module:
Animation—Remove/install LED-USB module
1128