Electrical installation
The manufacturer is not responsible if
you do not follow the safety precautions
from the Safety chapters.
This appliance is supplied without a main plug and a
main cable.
To access the electrical connections unscrew the 2 T20
screws on the rear panel top and take the panel out.
Applicable types of cables for Europe:
• Minimum size Cable / flex: 1,5 mm²
• Cable / flex type: H07 RN-F, H05 RN-F, H05 RRF,
H05 VV-F, H05 V2V2-F (T90), H05 BB-F
Applicable types of cables for UK only
Connection via Min. size cable / flex Cable / flex type Fuse
Oven Control Circuit 2,5 mm² PVC / PVC twin and earth 15 A min.
20 A max.
Energy efficiency
Product Fiche and information according to EU 65-66/2014
Supplier's name Neue
Model identification SFO2SS
Energy Efficiency Index 103.8
Energy efficiency class A
17