Width: 42 HP
Supply voltage (either):
Eurorack 10-pin header: +12V/-12V
USB power: +5V
Current draw:
Eurorack
+12V: typ. 65 mA, max. 100 mA
-12V: unused, 0 mA
5V: unused, 0 mA
USB
typ. 75 mA, max. 120 mA
CV inputs: 0V to 3.3V usable, -12V to 12V max.
Utility inputs: 0V to 5V usable, -12V to 12V max.
Audio input: ideal 3V-10V, max. 15V peak-to-peak (mono)
Audio output: 4V peak-to-peak (mono)
Connecting ELMYRA 2 to USB power
Connect the provided USB-A-to-USB-C cable (or any other such cable) to
a USB power source. Unlike typical USB-A jacks, the USB-A connector of
the provided cable is reversible. It may take a little more force to
fully insert on the USB-A side. The device will not work with a
USB-C-to-USB-C connection unless a USB-C-to-USB-A adapter is also
used. If you have previously removed the module unit from its case,
make sure the internal power cable is once again correctly inserted
into the white XH connector on the back of the board.
Connecting ELMYRA 2 to Eurorack power
Connect a 10-pin Eurorack power cable to the 2x5 power header on the
back of the module. There is an arrow indicator next to the word
STRIPE on the circuit board. Unsurprisingly, the red stripe side of
the cable goes on the side that says STRIPE. The module (and your
power supply) is protected in case you should ever connect it the
wrong way around, but it won’t turn on if you do.