EasyManua.ls Logo

NEW BRUNSWICK SCIENTIFIC Innova U725 - User Manual

Default Icon
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Ultra-Low Temperature
Freezers
innova
®
Range
(with vacuum insulation panel technology)
MANUAL No. M1288-0070
Revision E
October 29, 2007
NEW BRUNSWICK SCIENTIFIC CO., INC.
BOX 4005 44 TALMADGE ROAD EDISON, NJ 08818-4005
Telephone: 1-732-287-1200 1-800-631-5417
Fax: 732-287-4222 Telex: 4753012 NBSCO
Internet: http://www.nbsc.com E-mail: bioinfo@nbsc.com

Table of Contents

Questions and Answers

  • J
    jeremymedinaAug 5, 2025
    What to do if the NEW BRUNSWICK SCIENTIFIC Innova U725 shows high condenser temperature and I need to check the air filter?
    • Q
      qevansAug 5, 2025
      If the condenser temperature is too high on your NEW BRUNSWICK SCIENTIFIC Freezer, first check the air filter. It might be blocked; clean it following the instructions in Section 5.1.3. Also, the room temperature could be too high, so try to reduce it. If the fan has failed, you should call NBS Service department.
  • W
    william37Aug 9, 2025
    What to do if the NEW BRUNSWICK SCIENTIFIC Freezer displays high condenser temperature and check room temperature?
    • D
      Dylan BrewerAug 10, 2025
      If your NEW BRUNSWICK SCIENTIFIC Freezer displays a high condenser temperature and suggests checking the room temperature, it could be due to a few reasons. The ambient temperature might be too high, so try reducing it. Also, the freezer airflow may be blocked, or heated air from other equipment might be drawn into the freezer's air intake. Remove any airflow restrictions and ensure no other equipment is forcing hot air into the freezer intake. If the fan has failed, contact the NBS Service department.
  • Y
    Yolanda MartinezAug 13, 2025
    How to fix a NEW BRUNSWICK SCIENTIFIC Innova U725 Freezer door that won't open?
    • K
      Karen GambleAug 13, 2025
      If the door of your NEW BRUNSWICK SCIENTIFIC Freezer won’t open, there might be a few reasons. First, check if the handle is locked and unlock it with the key. Another reason may be ice buildup. Use the manual air vent plunger to break the ice (see Section 5.1.4) and allow time for the vacuum to leak away. If these steps don’t work, call an NBS Service representative.
  • N
    Nancy MontgomeryAug 18, 2025
    What happens when the NEW BRUNSWICK SCIENTIFIC Innova U725 has excessive condenser temperature and thermal overload?
    • A
      Angela CurtisAug 18, 2025
      If the NEW BRUNSWICK SCIENTIFIC Freezer reaches a critical condenser temperature, it will automatically shut down to prevent system damage. The thermal fuse will automatically reset after the system cools.
  • D
    dawnmartinAug 22, 2025
    What does it mean when the NEW BRUNSWICK SCIENTIFIC Innova U725 Freezer shows a low battery alarm?
    • A
      Andrew AlexanderAug 22, 2025
      If the NEW BRUNSWICK SCIENTIFIC Freezer displays a 'LOW BATTERY ALARM BATTERY CHARGE IS LOW' message, it indicates that the alarm battery charge is low. A consistently low battery charge may suggest a defective or worn battery.
  • B
    Bruce BurkeAug 27, 2025
    What does the 'DOOR OPEN ALARM' mean on my NEW BRUNSWICK SCIENTIFIC Freezer?
    • R
      Ryan ShahAug 27, 2025
      The system records and displays the time during which the outer door of your NEW BRUNSWICK SCIENTIFIC Freezer is held open.
  • F
    fmartinezAug 30, 2025
    What does the 'POWER FAILURE' message indicate on my NEW BRUNSWICK SCIENTIFIC Freezer?
    • J
      Janet GardnerAug 30, 2025
      The system records and displays the accumulated time since a power failure occurred with your NEW BRUNSWICK SCIENTIFIC Freezer.

Summary

Health and Safety Precautions

Workplace Safety Compliance

Adherence to UK's Health and Safety at Work Act 1974 requirements.

Declaration of Conformity

Warranty Information

Inspection & Unpacking

Box and Packing List Verification

Procedure for checking received equipment against the packing list.

Installation and Setup

Quick-Start Setup Guide

Step-by-step instructions for initial freezer setup.

Power Connection and Switch Operation

Procedure for connecting the power cord and operating the power switch.

Alarm System Activation

Instructions for enabling audible alarms and charging backup batteries.

Operation

Operating Features and Controls

Overview of the freezer's control panel and LCD display.

Menu System Navigation

Description of the main menu categories: PROG, USER, DATA, DIAG, HELP.

Temperature and Alarm Setpoints

How to set operating temperature and alarm thresholds.

Time, Date, and Alarm Functions

Setting the system clock and understanding various alarm types.

Modifying Alarm Functions

Customizing alarm delays and mute settings for better alert management.

Diagnostic Information and Testing

Accessing system parameters and performing function tests.

General Functional Guidelines

Maintenance

Troubleshooting

Error, Alarm, and Message Interpretation

Understanding and resolving error messages and system alerts.

Options & Accessories

Specifications

Drawings and Schematics

NEW BRUNSWICK SCIENTIFIC Innova U725 Specifications

General IconGeneral
BrandNEW BRUNSWICK SCIENTIFIC
ModelInnova U725
CategoryFreezer
LanguageEnglish

Related product manuals