32
Gas Connections
WARNING
Never connect a gas line directly to the grill. A pressure regulator must be installed on all gas
equipment. All local codes require a pressure regulator and NewAge supplies the correct regulator
with your grill. Removing or failing to install the pressure regulator can result in re, and serious
personal injury and will void the warranty. This grill is designed for non-combustible enclosures
only.
As indicated on the rating plate, this gas grill is designed to operate with gas supply pressure of
11” WC for Propane. This appliance is certied to be used only with 20 Lbs Propane tank. If the gas
supply pressure is lower than these requirements, the unit will be under-red and will not reach
the maximum temperatures. Ensure that the supply line size complies with local and/or national
installation codes.
The grill is factory set to use Propane gas. It is critical that the gas you use matches that which the
grill was set up for. You can verify that by checking the rating plate.
Rating Plate - Lists model numbers, and gas type
Water Column Requirements
NEWAGE PLATINUM 40” GRILL
(PROPANE GAS)
MODEL / MODÈLE
CLASS NO / CATÉGORIE #: 2711 04/84
3 X 16,000 BTU/ H MAIN BURNERS / BRÛLEUR PRINCIPAL
1 X 15,000 BTU/ IR ROTISSERIE BURNER / BRÛLEUR DE RÔTISSOIRE
1 X 15,000 BTU/ IR SEAR BURNER / BRÛLEUR SAISIR INFRAROUGE À
HAUTE TEMPÉRATURE
MFG DATE DE FABRICATION :
.CNI STCUDORP EGAWEN
ADANAC ,OIRATNO ,NAHGUAV
ENIHC NE EUQIRBAF /ANIHC NI EDAM
Class IIIA-2
111 CREDITVIEW ROAD, 2nd FLOOR
L4L-9T1
23 ”/584.2 MM
1 3/4”/32 MM
Supplier to APPLY
PRODUCTION CODE STICKER
PROPANEORIFICE SIZES/ GRANDEUR DES ORIFICS
H - MAIN BURNER/ BRÛLEUR PRINCIPAL
ROTISSERIE BURNER/ BRÛLEUR DE RÔTISSOIRE
SEAR STATION BURNER/BRÛLEUR INFRAROUGE
1.18MM
1.20MM
1.18MM
GRILL ELECTRICAL REQUIREMENTS:
INPUT- 110 VAC 60 Hz 0.25A
ROTISSERIE ELECTRICAL REQUIREMENTS:
INPUT- 110 VAC 60 Hz 0.04A
ANS Z21.58-2018•CSA 1.6-2018
Outdoor Cooking Gas Appliances
®
WARNING:
TURN OFF PROPANE GAS SUPPLY AT CYLINDER WHEN APPLIANCE IS
NOT IN USE. IF YOU PURCHASE A CHARCOAL TRAY, DO NOT PUT MORE THAN 0.7KG (1.5
LBS) OF CHARCOAL IN THE CHARCOAL TRAY. IF THESE INSTRUCTIONS ARE NOT
FOLLOWED EXACTLY, A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR.
ATTENTION:
COUPER L'ALIMENTATION EN GAZ PROPANE À LA BOUTEILLE SI
L’APPAREIL N’EST PAS UTILIS
É
. SI VOUS ACHETEZ UN PLATEAU À CHARBON, NE METTEZ PAS
PLUS DE 0,7 kg (1,5 LBS) DE CHARBON DANS LE PLATEAU À CHARBON. SI CES INSTRUCTIONS NE
SONT PAS SUIVIES EXACTEMENT, UN INCENDIE CAUSE LA MORT OU DES BLESSURES GRAVES
PEUVENT SURVENIR.
OUTDOOR COOKING APPLIANCE- FOR OUTDOOR USE ONLY. IF STORED INDOORS,
DETACH AND LEAVE CYLINDER OUTDOORS. DO NOT USE THIS APPLIANCE UNDER
OVERHEAD COMBUSTABLE SURFACES.
ONLY FOR INSTALLATION IN A BUILT-IN
ENCLOSURE CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS. /
APPAREIL DE
CUISINE DE PLEIN AIR- POUR UTILISATION À L’EXTÉRIEUR SEULEMENT. SI L’APPAREIL
EST ENTREPOSÉ À L’INTÉRIEUR, ENLEVER LES BOUTEILLES ET LES LAISSER À
L’EXTÉRIEUR. NE PAS UTILISER CET APPAREIL SOUS UNE SURFACE COMBUSTIBLE.
CONVIENT UNIQUEMENT POUR INSTALLATION DANS UNE ENCEINTE ENCASTRÉE
FAITE DE MATÉRIAUX INCOMBUSTIBLES.
CAUTION:
THIS APPLIANCE IS ADJUSTED AND SHIPPED FOR USE WITH PROPANE GAS. USE ONLY THE
GAS PRESSURE REGULATOR SUPPLIED WITH THIS APPLIANCE. THIS REGULATOR IS SET FOR AN OUTLET
PRESSURE OF 11” in WC (2.739 kPa). IF THE GAS SUPPLY PRESSURE IS LOWER THAN THESE REQUIREMENTS, THE
UNIT WILL BE UNDER-FIRED AND WILL NOT REACH THE MAXIMUM TEMPERATURES. ENSURE THAT THE SUPPLY
LINE SIZE COMPLIES WITH LOCAL AND/OR NATIONAL INSTALLATION CODES.
AVERTISSEMENT:
CET APPAREIL EST RÉGLÉ ET EXPÉDIÉ POUR UTILISATION AVEC DU GAZ
PROPANE. UTILISER UNIQUEMENT LE REGULATEUR DE PRESSION DE GAZ FOURNI AVEC CET APPAREIL. CE REGULATEUR
EST REGLE POUR UNE PRESSION DE SORTIE DE 11 POUCES DE COLONNE D”EAU (2.739 kPa). SI L'ALIMENTATION DE GAZ
LA PRESSION EST INFÉRIEURE À CES EXIGENCES, L'UNITÉ SERA SOUS-CUIT ET N'ATTAQUE PAS LES TEMPÉRATURES
MAXIMALES. ASSUREZ-VOUS QUE LA TAILLE DE LA LIGNE D'ALIMENTATION EST CONFORME AUX CODES
D'INSTALLATION NATIONAUX.
EQUIPPED FOR USE WITH
66911
66284
PLATINUM 40”
GRILL - LP
PLATINUM 40”
GRILL - LP WITH
40” GRILL CART
X
PROPANE
MINIMUM CLEARENCE FROM SIDES AND BACK OF UNIT TO
COMBUSTIBLE CONSTRUCTION, 14 INCHES FROM SIDES, AND 18
INCHES FROM BACK.
ONLY FOR INSTALLATION IN A BUILT-IN
ENCLOSURE CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS
OR NEWAGE GRILL CABINETS. SEE MODELS.
DÉGAGEMENT MINIMAL ENTRE LES PAROIS LATÉRALES ET L'ARRIÈRE
DE L'APPAREIL ET LA CONSTRUCTION COMBUSTIBLE, 14 POUCES À
PARTIR DES PAROIS LATÉRALES ET 18 POUCES À PARTIR DE
L'ARRIÈRE.
UNIQUEMENT POUR L'INSTALLATION DANS UN BOÎTIER
INTÉGRÉ CONSTRUIT DE MATÉRIAUX NON COMBUSTIBLES OU POUR
APPAREIL DE GRILLE ET D'ARMOIRES NEWAGE.
Fuel
WC Min Under
Full Load
PROPANE 11 in wc (LPG)
The rating plate is located in one or more of the following places:
• On the back of the grill
Ensure that the gas supplied meets with the minimum pressure requirements. Do not operate the
grill on any gas other than that for which the grill has been set.
Both the regulator and the manifold orices have been tuned for the type of gas specied on the
rating plate.
All installation and all installation parts must conform to local codes with the National Electrical
Code, ANSI Z223.1/ NFPA 70 latest edition and the National Fuel Gas Code, ANSI Z223.1/NFPA 54
in the U.S. and CGA-B149.1/.2 in Canada. Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)