EasyManua.ls Logo

Newage Platinum - Leak Testing Instructions; Testing a Gas Leak

Newage Platinum
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
Leak Testing Instructions
STOP
Testing a Gas Leak
Ensure all control knobs are in the o position.
Turn on the fuel supply.
• For Propane gas turn the cylinder valve knob counter clockwise one full
rotation.
Brush or spray a half-and-half solution of liquid soap and water onto all joints and connections of
the regulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. IMMEDIATELY turn o the gas supply.
See next page for “Fixing a Gas Leak
WARNING
This must be done before initial use, annually, and whenever any gas components
are replaced or serviced. Do not smoke while performing this test, and remove all
sources of ignition. See Leak Testing Diagram for areas to check. Never conduct a
leak test using re or ame. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak Testing Diagram
50% WATER
50% LIQUID
SOAP
Propane Gas
Spray
or
Brush